Reliability of the saliva self-sampling with and without supervision

původní článek
Creative Commons License IconCreative Commons BY Icon
vydavatelská verze
  • žádná další verze
Thumbnail
File can be accessed.Získat publikaci
Autor
Jaklová Dytrtová, JanaORCiD Profile - 0000-0002-6024-8679Scopus Profile - 23481684100
Dytrtová, Radmila
Kovač, IshakORCiD Profile - 0000-0002-3203-8308Scopus Profile - 57216484611
Šteffl, MichalORCiD Profile - 0000-0001-7297-8145WoS Profile - P-6804-2016Scopus Profile - 56418016300
Jakl, Michal

Zobrazit další autory

Datum vydání
2023
Publikováno v
Acta Universitatis Carolinae. Kinanthropologica
Ročník / Číslo vydání
59 (1)
ISBN / ISSN
ISSN: 1212-1428
Metadata
Zobrazit celý záznam
Kolekce
  • Fakulta tělesné výchovy a sportu

Tato publikace má vydavatelskou verzi s DOI 10.14712/23366052.2023.1

Abstrakt
One of the least invasive sampling methods suitable for self-sampling is saliva spitting. The aim of this study is to evaluate the suitability of saliva self-sampling for unsupervised testing. Two self-sampling strategies were compared on the basis of visual evaluation of samples, measurement of cortisol levels in samples and questionnaire survey. The saliva samples obtained by supervised self-sampling were found to be fully suitable for further analysis. In contrast, not all saliva samples obtained from unsupervised self-collection can be used: 13% non-compliance with the minimum required sample volume, 8% with some food/drink residues and 26% taken at the wrong day time. About 42% of the unsupervised probands made at least one significant error in the saliva self-collection procedure. These results indicate that the accuracy of the results based on the analysis of samples received from saliva self-sampling is limited. For clinical investigation, the presence of an inner standard (referring to the reliability of the sampling procedure) is required.
Klíčová slova
saliva sampling, cortisol responsibility, biosensors, hormones, immunoassays
Trvalý odkaz
https://hdl.handle.net/20.500.14178/2046
Licence

Licence pro užití plného textu výsledku: Creative Commons Uveďte původ 4.0 International

Zobrazit podmínky licence

xmlui.dri2xhtml.METS-1.0.item-publication-version-

DSpace software copyright © 2002-2016  DuraSpace
Kontaktujte nás | Vyjádření názoru
Theme by 
Atmire NV
 

 

O repozitáři

O tomto repozitářiAkceptované druhy výsledkůPovinné popisné údajePoučeníCC licence

Procházet

Vše v DSpaceKomunity a kolekcePracovištěDle data publikováníAutořiNázvyKlíčová slovaTato kolekcePracovištěDle data publikováníAutořiNázvyKlíčová slova

DSpace software copyright © 2002-2016  DuraSpace
Kontaktujte nás | Vyjádření názoru
Theme by 
Atmire NV